宇辰系統科技股份有限公司
  • Languages ( En )
    • 繁中
    • 简体
    • En
    CLOSE
  • About YCS
  • News & Events
    • Back
    • News Updates
    • Product Information
    • Technical Information
    • Exhibition Information
  • YCS Products
  • Integrator
  • Markets
    • Back
    • OUR Clients
  • Contact Us
    • Back
    • Global Locations
    • Contact YCS
  • Languages ( English )
    • Back
    • 繁體中文
    • 简体中文
    • English
  • Copyright © 2017 MIRACLE
  • Home
  • Integrator
  • MOXA
  • Serial Device Servers
Integrator
  • Allen-Bradley (AB)
    • Programmable Logic Controller
    • Low-Voltage Soft Starter
    • Variable Frequency Drive
    • Dynamic Voltage Sag Corrector (DySC)
  • ABB
    • PCS100 AVC-40
    • PCS100 UPS-I
    • Passive Components
      • MCB
      • MCCB
      • ACB
      • GCB
      • VCB
  • MOXA
    • Ethernet Switches
      • Layer 2 Managed Switches
      • Unmanaged Switches
      • Layer 2 Smart Switches
      • PoE Switches
      • Rackmount Switches
    • Wireless AP/Bridge/Client
    • Controllers & I/Os
    • Arm-Based Computers
    • Serial Device Servers
    • Protocol Gateways
    • Cellular Gateways/Routers
  • Schaffner
    • ECOSINE ACTIVE HARMONIC FILTER
    • ECOSINE PASSIVE HARMONIC FILTER
    • REACTORS
    • OUTPUT FILTERS
  • BALLUFF
    • Level Sensor
  • WAGO
    • Rail-Mount Terminal Blocks
      • 2000 series
      • 2001 series
      • 2002 series
      • 2004 series
      • 2006 series
      • 2010 series
      • 2016 series
      • 280 series
      • 281 series
    • Installation Terminal Blocks and Connectors
      • 733 Series
      • 734 Series
      • 773 Series
      • 222 Series
    • Relay and Optocoupler Modules
      • 788 Series
      • 857 Series
  • FIMER
    • Power Conversion System (PCS)
  • 自有品牌
    • Leak Controller
    • Wired RFID Fixed Reader
    • Electrical Leakage Protection System
  • TCC-80/80I Series 1
  • TCC-80/80I Series

TCC-80/80I Series

Production information
     The TCC-80/80I media converters provide complete signal conversion between RS-232 and RS-422/485, without requiring an external power source. The converters support both half-duplex 2-wire RS-485 and full-duplex 4-wire RS-422/485, either of which can be converted between RS-232’s TxD and RxD lines.

     Automatic data direction control is provided for RS-485. In this case, the RS-485 driver is enabled automatically when the circuitry senses the TxD output from the RS-232 signal. This means that no programming effort is required to control the transmission direction of the RS-485 signal.

Port Power over RS-232
     The RS-232 port of the TCC-80/80I is a DB9 female socket that can connect directly to the host PC, with power drawn from the TxD line. Regardless of whether the signal is high or low, the TCC-80/80I can obtain enough power from the data line. However, external power can be used if the handshake line is not available, if the serial cable is too long, or if the RS-232 device is a low-power device. For external power, a five to twelve VDC power supply can be connected using an adapter or a USB power cord.

Port Power Dissipation
     When installing a TCC-80 or TCC-80I converter, it is important to pay attention to power consumption, RS-232 cable length, and RS-422/485 transmission distance. In general, the TCC-80 and TCC-80I obtain 50 mW of power from the power source. Standard PC COM ports can provide 70 to 90 mW of power if the TxD, RTS, and DTR lines are connected. Moreover, the RS-232 cable should be shorter than 15 m (@ 9600 bps) to ensure that less power is lost from the host/device to the TCC-80. The remainder of the supplied power is used for transmitting the RS-422/485 signal.

Port Power and Optical Isolation
     The RS-232 port of the TCC-80/80I is a DB9 female socket that can connect directly to the host PC, with power drawn from the TxD line. Electrical 2.5 kV isolation for the TCC-80I is achieved with a photo coupler that transforms the electrical signal into light, and then re-transforms the light back into an electrical signal on the other side. In this way, the two electrical circuits are completely isolated from each other. This also protects the devices from ground loop currents, reduces damage caused by data loss, and prevents damage to the communication interfaces.


LED Port Power Indicator
     It’s easy enough to test the serial device with a multimeter to determine that the serial device will provide enough power to the media converter. However, it’s even easier to let the TCC-80I test the device for you. Simply connect the TCC-80I to the device’s RS-232 port and set the SW4 switch to Test mode. If the port power LED indicator lights up, the TCC-80I is receiving enough power. If the LED does not light up, you will need to attach an external power source to the TCC-80I.
back

About YCS

  • About YCS
  • Values and Business Philosophy
  • History
  • Service items
  • YCS Organization
  • Certification
  • Occupational Health and Safety Policy
  • Information Security Policy
  • ISO Certification/Special Honor

News & Events

  • News Updates
  • Product Information
  • Technical Information
  • Exhibition Information

Integrator

  • Allen-Bradley (AB)
  • ABB
  • MOXA
  • Schaffner
  • WAGO
  • FIMER

YCS Products

  • High-Tech Factory Management System
  • Cybersecurity
  • Equipment monitoring system

Markets

  • OUR Clients

Contact US

  • Global Locations
  • Contact YCS
 
TEL +886 3-563 2228 
FAX+886 3-573 7229
ADD4F., No. 5, Ln. 91, Dongmei Rd., East Dist., Hsinchu City 300-043 , Taiwan (R.O.C.)
High-quality hardware equipment ∣ Perfect software and hardware integration∣Professional FAE team
采用全球最先进SSL 256bit传输加密机制建议使用Chrome、Firefox、Safari最新版本浏览Design by WebTech 网页设计
Social Media
MailContact
go top