BRANDS
Leak Sensing Cable
Private Brand/Leak Controller
Production Information
• Complies with UL 910 and RoHS certifications
• Made in the USA.
• Core material is made of fire-resistant fluoropolymer; flame-retardant and non-combustible
• Maximum tensile strength: 725 N/mm²; maximum puncture resistance: 225 N/mm²
• Cable surface can be wiped dry and reused; unaffected by crystallized chemicals
Detail Information
- Basic acid and alkali resistance
- Detects liquid leakage at a length of 10 mm or a height of 20 mm; response time: 3 seconds; reset time: 15 seconds
- Operating temperature: -20°C to 75°C
- Humidity: 5% to 95% non-condensing
- Sensor cable length: up to 500 meters
- Leak location accuracy: within 50 cm
- Sensor cable resumes operation within 15 seconds after being wiped dry following a leak.